Product Details:
|
Conductor Material: | CU AL | Jacket Material: | XLPE PVC Rubber Mineral |
---|---|---|---|
Insulation Material: | XLPE PVC Rubber Mineral | Color: | Black Customized |
Voltage: | 0.6/1kV, 8.7/15kV, 26/35kv | Packing: | Wooden(Steel) Drum, Steel-wooden Drums |
Type: | LV MV HV Electric Cable | Armour: | SWA STA AWA |
Highlight: | armored power cable,armored electrical wire |
35kv Armoured Electrical Cable 240mm2 Power Cable For Transformer Stations
Construction
Conductor | Compact Stranded Copper Conductor, Class 2 as per IEC 60228 |
Circular solid Copper Conductor, Class 1 as per IEC 60228 | |
Insulation | XLPE(Cross-linked polyethylene) |
Filler | PP Filler |
Wrapping Tape | Non woven |
Inner Covering | Extruded PVC |
Armour | Steel Wire |
Overall Sheath | Termite Resistant PVC |
Applications
Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism,
heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple
structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Standards
International: IEC 60502-2, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request
Technical data
Rated voltage: 0.6/1kV
Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables
15 x cable O.D for single-core armoured cables
15 x cable O.D for multi-core non-armoured cables
12 x cable O.D for multi-core armoured cables
Specifications
Nom. Cross-section of conductor |
Strands No./Dia. Of Conductor |
Insulation Thickness | Inner Covering Thickness | Dia. Of Armor Wire | Sheath Thickness | Approx. O.D. |
Approx. Weight |
Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | pc/mm | mm | mm | (mm) | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
4 × 4 | 7/0.85 | 0.7 | 1.0 | 0.9 | 1.8 | 18.0 | 699 | 4.61 | 3.5 | 34 | 45 |
4 × 6 | 7/1.04 | 0.7 | 1.0 | 1.25 | 1.8 | 19.0 | 820 | 3.08 | 3.5 | 43 | 57 |
4 × 10 | 7/1.38 | 0.7 | 1.0 | 1.25 | 1.8 | 22.0 | 1233 | 1.83 | 3.5 | 60 | 77 |
4 × 16 | 7/1.78 | 0.7 | 1.0 | 1.6 | 1.8 | 24.5 | 1550 | 1.15 | 3.5 | 83 | 105 |
4 × 25 | 7/2.14 | 0.9 | 1.0 | 1.6 | 1.8 | 29.2 | 2036 | 0.727 | 3.5 | 105 | 125 |
4 × 35 | 7/2.52 | 0.9 | 1.0 | 2.0 | 1.9 | 32.5 | 2501 | 0.524 | 3.5 | 125 | 155 |
4 × 50 | 10/2.52 | 1.0 | 1.0 | 2.0 | 2.0 | 33.0 | 3064 | 0.387 | 3.5 | 160 | 185 |
4 × 70 | 14/2.52 | 1.1 | 1.0 | 2.0 | 2.1 | 37.0 | 3974 | 0.268 | 3.5 | 200 | 225 |
4 × 95 | 19/2.52 | 1.1 | 1.2 | 2.0 | 2.3 | 43.0 | 5032 | 0.193 | 3.5 | 245 | 270 |
4 × 120 | 24/2.52 | 1.2 | 1.2 | 2.5 | 2.5 | 45.0 | 6327 | 0.153 | 3.5 | 285 | 310 |
4 × 150 | 30/2.52 | 1.4 | 1.4 | 2.5 | 2.7 | 51.0 | 7765 | 0.124 | 3.5 | 325 | 345 |
4 × 185 | 37/2.52 | 1.6 | 1.4 | 2.5 | 2.8 | 56.0 | 9205 | 0.0991 | 3.5 | 375 | 390 |
4 × 240 | 48/2.52 | 1.7 | 1.4 | 2.5 | 3.0 | 62.0 | 11444 | 0.0754 | 3.5 | 440 | 450 |
4 × 300 | 61/2.52 | 1.8 | 1.6 | 2.5 | 3.2 | 67.0 | 13830 | 0.0601 | 3.5 | 505 | 515 |
4 × 400 | 61/2.97 | 2.0 | 1.6 | 3.15 | 3.5 | 74.0 | 19673 | 0.0470 | 3.5 | 570 | 575 |
Certificate:
package details:
Contact Person: Zhang
Fax: 86--66299899