Product Details:
|
Application: | Construction,Customized Electrical Wire Power Cable | Jacket: | PVC,XLPE |
---|---|---|---|
Insulation Material: | XLPE | Standard: | IEC60502,GB/T12706 |
Rated Voltage: | 600/1000 Volts | Name: | Armoured Electrical Cable |
High Light: | armored power cable,armored electrical wire |
PVC Sheath Armored Power Cable Fire Resistant Copper Cores XLPE Insulated
The construction of fire resistant cable armoured electrical cable
a,stranded (RM) bare copper
b, Mica Tape for Fire Resistant
c,core insulation of cross-linked polyethylene
d, Fillers
e,Wrapping tape or Flame Retardant tape
f,PVC Inner Bedding
g, Galvanized Steel Wire Armour
houter sheath of polyvinylchloride (PVC)
1. Heat resistance: The mesh XLPE has excellent heat resistance.Does not decompose under 200 °C and carbonization, long-term working temperature is 90 °C, hot life up to 40 years.
2. Insulation performance: XLPE maintains the good insulation characteristics of PE, and the insulation resistance further increases.The tangent of dielectric loss Angle is very small, and it is not affected by temperature.
3. Mechanical properties: The hardness, stiffness, abrasion resistance and impact resistance of XLPE are improved due to the establishment of new chemical bonds between macromolecules, thus making up for the vulnerability of PE to environmental stress and cracking.
4. Chemical resistance: XLPE has strong acid and alkali resistance and oil resistance, and its combustion products are mainly water and carbon dioxide, which are less harmful to the environment and meet the requirements of modern fire safety.
Fire resistant copper cores XLPE insulated PVC sheath Armoured Electrical Cable
Nom. Cross-section of conductor |
Strands |
Insulation Thickness | Inner Covering Thickness | Dia. Of Armor Wire | Sheath Thickness | Approx. O.D. |
Approx. |
Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | pc/mm | mm | mm | (mm) | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
4 × 4 | 7/0.85 | 0.7 | 1.0 | 0.9 | 1.8 | 18.0 | 699 | 4.61 | 3.5 | 34 | 45 |
4 × 6 | 7/1.04 | 0.7 | 1.0 | 1.25 | 1.8 | 19.0 | 820 | 3.08 | 3.5 | 43 | 57 |
4 × 10 | 7/1.38 | 0.7 | 1.0 | 1.25 | 1.8 | 22.0 | 1233 | 1.83 | 3.5 | 60 | 77 |
4 × 16 | 7/1.78 | 0.7 | 1.0 | 1.6 | 1.8 | 24.5 | 1550 | 1.15 | 3.5 | 83 | 105 |
4 × 25 | 7/2.14 | 0.9 | 1.0 | 1.6 | 1.8 | 29.2 | 2036 | 0.727 | 3.5 | 105 | 125 |
4 × 35 | 7/2.52 | 0.9 | 1.0 | 2.0 | 1.9 | 32.5 | 2501 | 0.524 | 3.5 | 125 | 155 |
4 × 50 | 10/2.52 | 1.0 | 1.0 | 2.0 | 2.0 | 33.0 | 3064 | 0.387 | 3.5 | 160 | 185 |
4 × 70 | 14/2.52 | 1.1 | 1.0 | 2.0 | 2.1 | 37.0 | 3974 | 0.268 | 3.5 | 200 | 225 |
4 × 95 | 19/2.52 | 1.1 | 1.2 | 2.0 | 2.3 | 43.0 | 5032 | 0.193 | 3.5 | 245 | 270 |
4 × 120 | 24/2.52 | 1.2 | 1.2 | 2.5 | 2.5 | 45.0 | 6327 | 0.153 | 3.5 | 285 | 310 |
4 × 150 | 30/2.52 | 1.4 | 1.4 | 2.5 | 2.7 | 51.0 | 7765 | 0.124 | 3.5 | 325 | 345 |
4 × 185 | 37/2.52 | 1.6 | 1.4 | 2.5 | 2.8 | 56.0 | 9205 | 0.0991 | 3.5 | 375 | 390 |
4 × 240 | 48/2.52 | 1.7 | 1.4 | 2.5 | 3.0 | 62.0 | 11444 | 0.0754 | 3.5 | 440 | 450 |
4 × 300 | 61/2.52 | 1.8 | 1.6 | 2.5 | 3.2 | 67.0 | 13830 | 0.0601 | 3.5 | 505 | 515 |
4 × 400 | 61/2.97 | 2.0 | 1.6 | 3.15 | 3.5 | 74.0 | 19673 | 0.0470 | 3.5 | 570 | 575 |
Fire resistant copper cores XLPE insulated PVC sheath Armoured Electrical Cable